النطاق الفني

Thin-film architectural and structural steel fireproofing with verifiable DFT.

Intumescent coatings provide thin-film, profile-following fire protection for exposed structural steel where architectural aesthetics, clean lines, and minimal dead weight are critical design priorities.

Under high temperatures, the coating expands up to 50 times its original dry film thickness, generating a robust insulating carbonaceous char that insulates load-bearing steel against critical failure temperatures (typically 550°C for beams and 500°C for columns).

Vortexen coordinates solvent-borne and water-borne systems for 30 to 120-minute cellulosic fire exposure. Each member is calculated from exact section factor geometry (Hp/A or A/V), substrate primer compatibility, and environmental application conditions (temperature ≥ 3°C above dew point, relative humidity ≤ 85%) with calibrated magnetic/electromagnetic dry film thickness (DFT) verification.

DesignSection factor
ApplicationDFT-led
SystemCompatible build-up
01 / Buyer outcome

What this route should produce

  • Manufacturer-based thickness schedule
  • Visible primer and topcoat compatibility
  • Layer and environment records
  • Final DFT and rectification report
02 / البيانات المطلوبة

What we need to qualify it

  • Steel schedule and geometry
  • Required rating
  • Critical temperature
  • Primer system
  • Environment and exposure
  • Architectural finish
01 / Scope

What the route can cover

  • Architecturally exposed structural steel (AESS)
  • Internal and semi-exposed columns, beams, and hollow sections
  • Solvent-borne systems for fast curing and semi-exposed service
  • Water-borne acrylic systems for enclosed and occupied spaces
  • Section factor (Hp/A and A/V) calculation and thickness schedules
  • Anti-corrosive primer compatibility and approved decorative topcoats
  • Systematic magnetic/electromagnetic dry film thickness (DFT) gauge surveys
  • Repair and reinstatement of damaged coating areas
02 / مسار التنفيذ

How work moves forward

  1. Validate approved system and thickness schedule
  2. Inspect surface and primer
  3. Control temperature, humidity and dew point
  4. Apply in measured coats
  5. Inspect DFT, repair defects and close out
03 / الأدلة المطلوبة

What buyers should expect

  • Approved product and system data
  • Thickness schedule
  • Environmental logs
  • Wet- and dry-film inspection records

Commercial and technical guardrails

What this route refuses to hide.

Fast progress is valuable only when assumptions, responsibility and limitations remain visible to the buyer and delivery team.

  • 01No generic DFT assumption
  • 02No application over unknown primer
  • 03No accelerated recoating outside limits
  • 04No unrecorded site repair